128
Valves
High Pressure Valves
Part No. Description
Qty.
REPLACEMENT PODS
PD715-000 Rapid Replacement Pod
™
for MXT715-100
ea.
PD715-102 Rapid Replacement Pod for MXT715-102
ea.
PD715-105 Rapid Replacement Pod for MXT715-105
ea.
PD7900 Rapid Replacement Pod for MXP7900-000
ea.
PD7920 Rapid Replacement Pod for MXP7920-000
ea.
PD7960 Rapid Replacement Pod for MXP7960-000
ea.
PD7970 Rapid Replacement Pod for MXP7970-000
ea.
PD7980 Rapid Replacement Pod for MXP7980-000
ea.
PD7986 Rapid Replacement Pod for MXP7986-000
ea.
PD9900 Rapid Replacement Pod for MXP9900-000
ea.
PD9960 Rapid Replacement Pod for MXP9960-000
ea.
Replacement FITTINGS
6000-209 Stainless Steel Standard Fittings,
with 6000-210 Ferrules, 1/16”, 10-32
10-pk
6000-282 RheFlex One-piece Fittings, 1/16”, 10-32, PEEK
™
, Natural 10-pk
6000-360 M4 RheFlex Fittings, 1/32”, PEEK, Natural
10-pk
Fast Chromatography Sample Loops
Part No. Description
Pressure Rating Volume Qty.
7755-300 Stainless Steel Sample Loop 30,000 psi (2,070 bar) 5 µL ea.
7755-301 Stainless Steel Sample Loop 30,000 psi (2,070 bar) 10 µL ea.
7755-302 Stainless Steel Sample Loop 30,000 psi (2,070 bar) 20 µL ea.
7755-303 Stainless Steel Sample Loop 30,000 psi (2,070 bar) 50 µL ea.
7755-304 Stainless Steel Sample Loop 30,000 psi (2,070 bar) 100 µL ea.
Replacement FITTINGS
VHP-200x VHP Stainless Steel Fitting
for 1/16” OD tubing
30,000 psi (2,070 bar)
10-pk
VHP-320x VHP Reusable Fitting
for 1/16” OD tubing
25,000 psi (1,724 bar)
10-pk
Application Note
The high pressure MX Series II can increase sample throughput and
laboratory productivity by automating HPLC applications. These applications
can be automated with the addition of the high pressure MX Series II valve to
an existing HPLC System, saving money and allowing for simple connections
with little set-up time.
Alternating column regeneration using
Rheodyne
®
Two-Position, Ten-Port MXP Module
(P/N MXP7960-000, page 127)
Sample
Injector
Eluent
Pump
Column 2
Waste
Detector
Column 1
Regeneration Pump
Regeneration Pump
Eluent
Pump
Sample
Injector
Column 2
Waste
Detector
Column 1
Position A
Position B
1
1
2
3
4
5
6
7
8
9
10
2
3
4
5
6
7
8
9
10
1
1
6
6
5
5
4
4
3
3
2
2
Flow path of MX Series II Six-Position, Seven-Port Selector Valve
7
6
1
2
3
4
5
Flow path of MX Series II Two-Position, Six-Port as an Injection Valve
Flow path of MX Series II
™
Two-Position, Six-Port Switching Valve
Position 1
Position 2
Flow path of MX Series II Two-Position, Ten-Port Switching Valve
Position 1
Position 2
1
2
3
4
5 6
7
8
9
10
1
2
3
4
5 6
7
8
9
10
Inject
6
5
4
3
2
1
Column
Pump
Waste
Sample
Load
6
5
4
3
2
1
Column
Pump
Waste
Sample
FOR ORDERING & DISTRIBUTOR INFORMATION +1 800 426 0191 • +1 360 679 2528 • www.idex-hs.com