Page 163 - IDEX_Catalog20112012

This is a SEO version of IDEX_Catalog20112012. Click here to view full version

« Previous Page Table of Contents Next Page »
161
Filters & Frits
PrecolumnFilters
0.5 µm or 2 µm porosity frits available
Great column protection
Feature stainless steel bodies and polymer-encased stainless steel frits
Upchurch Scientifc
®
Standard Precolumn Filters have 0.020” (0.50mm)
diameter thru-holes and 8° distribution cones for minimal band
spreading andmixing. They feature stainless steel bodies, and pressure
rated to 6,000 psi (414 bar) and both accept 1/16” OD tubing and
standard 10-32 threaded high pressure fttings.
With a 0.010” (0.25mm) diameter thru-hole, our A-318 Filter has one of
the lowest swept volumes (0.61µL*) of any analytical HPLC precolumn
flter available, ensuring maximum protection with very little band
broadening. Pressure rated to 6,000 psi (414 bar).
A-318
Precolumn Filter
0.48”
(1.22 cm)
1.00”
(2.54 cm)
A-102
0.5 µm SST frit
Inline Solvent Filters
Excellent for general purpose inline use
2 µm and 20 µm porosity frits available
Placed between the pump and sample injection valve, Inline Solvent
Filters trap particles released through normal piston seal wear. Without
an inline flter, particles can be fushed through your system’s tubing
to the sample injection valve, resulting in valve damage and further
system contamination.
These filters are pressure rated to 6,000 psi (414 bar) and use a
2 µm or 20 µm stainless steel frit. An 8° distribution cone helps
spread the fow of the mobile phase over the entire surface of the
frit, while the 0.050” (1.3 mm) diameter thru-hole allows virtually
unrestricted solvent fow rates.
A-314
Inline Solvent Filter
0.49”
(1.24 cm)
0.94”
(2.39 cm)
A-100
2 µm SST frit
A-313
Inline Solvent Filter
0.49”
(1.24 cm)
0.94”
(2.39 cm)
A-224
20 µm Semi-
Prep SST frit
Precolumn and Inline Filters
Part No. Description
Porosity
Threads
Includes
Swept Volume*
Pressure Rating
Precolumn Filters
A-315
Solvent Filter Assembly
2 µm
10-32 Coned
(1) A-101
1.4 µL
6,000 psi (414 bar)
A-316
Solvent Filter Assembly
0.5 µm
10-32 Coned
(1) A-102
1.3 µL
6,000 psi (414 bar)
A-318
Solvent Filter Assembly
0.5 µm
10-32 Coned
(1) A-102
0.84 µL
6,000 psi (414 bar)
A-101x Replacement Frits, Stainless Steel, 10-pk
2 µm
0.74 µL
N/A
A-102x Replacement Frits, Stainless Steel, 10-pk
0.5 µm
0.61 µL
N/A
Inline Solvent Filters
A-313
Solvent Filter Assembly
20 µm
10-32 Coned
(1) A-224
12.3 µL
6,000 psi (414 bar)
A-314
Solvent Filter Assembly
2 µm
10-32 Coned
(1) A-100
4 µL
6,000 psi (414 bar)
A-100x Replacement Frits, Stainless Steel, 10-pk
2 µm
1.4 µL
N/A
A-224
Replacement Frits, Stainless Steel, ea.
20 µm
9.7 µL
N/A
*Swept volumes include/refect theoretical frit volume values.
A-315
Precolumn Filter
0.49”
(1.24 cm)
0.94”
(2.39 cm)
A-101
2 µm SST frit
0.49”
(1.24 cm)
0.94”
(2.39 cm)
A-102
0.5 µm SST frit
A-316
Precolumn Filter
Top Seller
See starred products
Fittings
All flters on these two pages have 10-32 internal threads for 1/16” OD tubing,
conveniently allowing the use of Fingertight Fittings. Use any of the all-
polymer 10-32 Fingertight Fittings found on pages 11, 13 and 15 with these
flters. For the stainless steel flters, you may also use the 10-32 stainless steel
fttings on page 10.
Frits
Any of the polymer-ring encased frits from pages 167 – 171 with an overall
diameter of 0.247” to 0.254” can be used with the flters on this page and the
biocompatible precolumn flters.
Related Products
FOR ORDERING & DISTRIBUTOR INFORMATION +1 800 426 0191 • +1 360 679 2528 • www.idex-hs.com