185
Column Hardware
Sample Trap Columns
Capillary SampleTrapColumns
Packed and unpacked columns
Pressure rated to 5,000 psi (345 bar)
Direct connect 360 µm OD capillary tubing
Upchurch Scientific
®
Capillary Sample Trap Columns are ideal for
separating and concentrating and/or purifying biological samples.
Capillary Sample Trap Column Assemblies include one or more 1 µm
NanoFilter
™
Capsules, each containing either a stainless steel (SST) or
biocompatible titanium (Ti) frit. The swept volume of these unique flters
is only 10 nL each. Connect your 360 µm OD capillary tubing directly
to our Sample Trap Column Assemblies using the fttings provided.
The maximum fow rate for these products is 10 µL/min; 250 nL is the
optimal fow rate.
Please Note: Reversing flow in these columns can result in loss of
packing material. For more information regarding the proper setup
involving these Sample Trap Columns, please contact your local
distributor or IDEX Health & Science customer service.
C-1200
C-1400
C-1300
Packing material specifcations: C18, high carbon load, 5 µm/300A
spherical silica and SCX, 5 µm 85A material
Maximum sample loading capacity of 0.1 µg and capillary bed volume
of 0.19 µL or less
Note
Top Seller
SEE STARRED PRODUCTS
Part No. Description
Frit
Material Includes
CAPILLARY SAMPLE TRAP COLUMNS
Assemblies
C-1200 C18 Column
SST
(1) 2-pk C-1250, (1) M-125,
(2) P-416, (2) F-152, (1) M-124NF
C-1300 C18 Column
Ti
(1) 2-pk C-1250, (1) M-126,
(2) P-416BLK, (2) F-152, (1) M-124NF
C-1400 Strong Cation Exchange
(SCX) Column
Ti
(1) 2-pk C-1450, (1) M-126,
(2) P-416G, (2) F-152, (1) M-124NF
C-1500 Unpacked Column
SST
(1) FS-1000-25, (2) M-125,
(2) P-416, (2) F-152
C-1600 Unpacked Column
Ti
(1) FS-1000-25, (2) M-126,
(2) P-416BLK, (2) F-152
Column Coupler and Replacement Parts
Part No. Description
Swept
Volume Qty.
C-1210 Column Coupler, PEEK
—
ea.
C-1250 C18 Columns, 100 µm ID x 2.5 cm x 360 µm OD —
2-pk
C-1450 Strong Cation Exchange (SCX) Columns
100 µm ID x 2.5 cm x 360 µm OD
—
2-pk
F-152 MicroFerrule for 360 µm OD tubing, PEEK —
ea.
FS-1000-25 UnpackedColumn, 100µmIDx2.5cmx360µmOD —
ea.
M-124NF Capsule Union, no Frit, PEEK
9.5 nL ea.
M-125
1 µm NanoFilter Capsules, with SST Frits
10 nL
2-pk
M-126
1 µm NanoFilter Capsules, with Ti Frits
10 nL
2-pk
P-416
Female Nut, Natural PEEK
—
ea.
P-416BLK Female Nut, Black PEEK
—
ea.
P-416G Female Nut, Green PEEK
—
ea.
Ferrule (b)
Qty. = 2
Flow
NanoFilter (d)
Filter Holder (c)
Qty. = 2
Column Holder
Column (e)
Capsule Union or NanoFilter (f)
Nut (a)
Qty. = 2
Column
Assembly
Nuts
(a)
Ferrules
(b)
Filter
Holder
Color(c)
NanoFilter
(d)
Column (e)
Capsule
Union or
NanoFilter (f)
C-1200
P-416 F-152 Tan M-125 (SST) C-1250 (C18) M-124NF (no frit)
C-1300
P-416BLK F-152 Tan M-126 (Ti) C-1250 (C18) M-124NF (no frit)
C-1400
P-416G F-152 Black M-126 (Ti) C-1450 (SCX) M-124NF (no frit)
C-1500
P-416 F-152 Tan M-125 (SST) FS-1000-25 (unpacked) M-125 (SST)
C-1600
P-416BLK F-152 Tan M-126 (Ti) FS-1000-25 (unpacked) M-126 (Ti)
All nuts, ferrules, and column holders are made of PEEK polymer. Filter holders are made of PEEK polymer
(non-conductive) or stainless steel (conductive). NanoFilter Capsule bodies are made of PEEK polymer (non-
conductive) or stainless steel and PEEK (conductive). See page 165 for NanoFilter Capsule color coding.
Abbreviation Key: SST = stainless steel; Ti = titanium; SCX = Strong Cation Exchange
Components Chart
Please refer to the drawing and part numbers below when ordering
replacement components:
C-1210
Column coupler
Related Products
Use the P-116 MicroFerrule Plug on page 18 to plug a Sample Trap
Column for storage
Find 360 µm OD PEEK
™
polymer and fused silica tubing on page 65
FOR ORDERING & DISTRIBUTOR INFORMATION +1 800 426 0191 • +1 360 679 2528 • www.idex-hs.com