39
Connectors
High Pressure Capillary Unions
Part No. Description
Threads
Includes
Thru-hole
Swept Volume Pressure Rating
MICROTIGHT UNIONS
P-720 PEEK True ZDV Union for MicroTight Sleeves
6-32 Coned
(2) F-125, (1) P-553
N/A
N/A
4,000 psi (276 bar)
P-771 PEEK True ZDV Union for 1/32” OD Tubing
6-32 Coned
(2) F-126S, (1) P-553
N/A
N/A
5,000 psi (345 bar)
P-772 PEEK Union for 360 µm OD Tubing
5/16-24 Coned
(2) F-152, (2) P-416BLK
0.006” (0.150 mm) 5 nL
5,000 psi (345 bar)
P-874 PEEK MicroElbow for MicroTight Sleeves
5/16-24 Coned
(2) F-172, (2) P-416
0.006” (0.150 mm) 20 nL
4,000 psi (276 bar)
REPLACEMENT GAUGE PLUGS (TO ACHIEVE TRUE ZDV CONNECTIONS WITH OUR P-720 AND P-771 UNIONS)
P-553 Gauge Plug, Delrin
®
6-32 Coned N/A
N/A
N/A
N/A
CONDUCTIVE MICROTIGHT UNIONS
M-539 Conductive Union for 1/32” OD tubing, PEEK/SST
5/16-24 Coned
(2) F-112, (2) P-416, (1) M-138NF
0.006” (0.150 mm) 5nL
5,000 psi (345 bar)
M-572 Conductive Union for 360 µm OD Tubing, PEEK/SST 5/16-24 Coned
(2) F-152, (2) P-416BLK, (1) M-128NF 0.011” (0.279 mm) 16 nL
5,000 psi (345 bar)
INSULATING MOUNTING BRACKET
M-447
Insulating Mounting Bracket
N/A
N/A
N/A
N/A
N/A
Conductive MicroTightUnions
The Upchurch Scientifc Conductive MicroTight Unions manufactured
by IDEXHealth&Science provide an excellent opportunity to introduce
voltage into an electrospray or capillary electrophoresis system. With
an extremely low internal volume of 16 nL or 5 nL, these unions can be
placed inlinewith 360 μmor 1/32”ODcapillary tubing. Mount and apply
voltage to these unions using our Insulating Mounting Bracket below.
InsulatingMountingBracket
Use our Insulating Mounting
Bracket to easily integrate the
Conductive Mini MicroFilters
shown above into your system
or lab.
The product snaps into place.
Voltage from your lead wire
is conducted through the
attaching stainless steel nut
and screw (included), then
onto the mounted product
via the stainless steel clip.
The bracket’s base includes two holes (#2 screw clearance) for easy
mountingontoany labsurface. Dimensionsare1.25”Lx0.45”Wx0.63”H.
Insulating Mounting Bracket, shown with lead wire and
Conductive MicroTight Union, not included.
M-572
Conductive MicroTight Union
for 360 µm OD tubing
with fttings and Capsule Union included
0.76”
(1.93 cm)
0.38”
(0.97 cm)
M-539
Conductive MicroTight Union
for 1/32” OD tubing
with fttings and Capsule Union included
0.76”
(1.93 cm)
0.38”
(0.97 cm)
For an example of using a conductive MicroTight Union in a pressure driven
ion preconcentration application see: “Self-Sealed Vertical Polymeric
Nanoporous Junctions for High Throughput Nanofuidic Applications.“
Sun Jae Kim and Jong Yoon Han. Analytical Chem. 2008, 80: 3507-3511
Application Note
MicroTight
®
Connectors for Capillary Tubing
Connect two pieces of capillary tubing with these Upchurch Scientifc
®
PEEK
MicroTight Connectors. The True ZDV Unions allow two pieces
of tubing to connect directly to each other—using the included gauge
plug to ensure proper alignment. The standard union and elbow both
feature a 0.006” (0.150 mm) thru-hole, adding only a small amount of
additional fow-path volume to help ensure proper chromatographic
results. For MicroTight unions designed for UHPLC applications, see
page 37.
P-720
MicroTight True ZDV Union
for use with MicroTight Sleeves
with fttings and gauge plug included
0.76”
(1.93 cm)
0.25”
(0.64 cm)
6-32
6-32
0.76”
(1.93 cm)
0.25”
(0.64 cm)
6-32
6-32
P-771
MicroTight True ZDV Union
for 1/32” OD tubing
with fttings and gauge plug included
P-772
MicroTight Union
for 360 µm OD tubing
with fttings included
0.81”
(2.06 cm)
0.31”
(0.79 cm)
5/16-24
5/16-24
0.44”
(1.12 cm)
P-874
MicroElbow for
MicroTight Tubing Sleeves
with fttings included
0.125” (0.32 cm)
hole diameter
1.00”
(2.54 cm)
0.31”
(0.79 cm)
0.81”
(2.06 cm)
Top Seller