Page 56 - IDEX_Catalog20112012

This is a SEO version of IDEX_Catalog20112012. Click here to view full version

« Previous Page Table of Contents Next Page »
54
Connectors
NanoPort
Assemblies
NanoPort Assemblies
For lab-on-a-chip applications
Options to connect 360 µm, MicroTight
®
tubing sleeves, 1/32” OD
or 1/16” OD tubing
Wetted materials: PEEK
and perfuoroelastomer
Upchurch Scientifc
®
NanoPort Assemblies are the frst commercially
available products to provide consistent fluid connections for
chip-based analyses. Once attached, NanoPort connections can
withstand pressures to 1,000 psi (69 bar).* NanoPorts will adhere to
silicon, quartz, glass and some polymers.
All NanoPort components are made of inert, biocompatible PEEK
polymer (nuts and ports) and Perlast
®
perfuoroelastomer (ferrules and
gaskets). These products bond easily to chip surfaces with the provided
Preformed Adhesive Rings (see Application Note on the following
page). Their unique design also prevents adhesive contamination of
the fuid path. AndNanoPort connections add no additional volume to
the fuid path, virtually eliminating dead volume traditionally associated
with chip-based fuid connections.
Our NanoPort Reservoir Assembly is designed for open well
applications, such as CE.
*Except the N-333 NanoPort Assembly, which is rated to 500 psi (34.5 bar).
6-32 Flat-Bottom
Assemblies
Tubing
(not included)
6-32 FB
2-Piece Fitting
Ferrule
6-32 FB
NanoPort
Gasket
0.25”
(6.4 mm)
0.28”
(7.1 mm)
0.33”
(8.4 mm)
6-32 Coned Assemblies
0.33”
(8.4 mm)
0.25”
(6.4 mm)
0.38”
(9.7 mm)
6-32 Coned
NanoPorts
Tubing
(not included)
6-32 Coned
1-Piece Fitting
Gasket
10-32 Flat-Bottom
Assemblies
0.25”
(6.4 mm)
0.33”
(8.4 mm)
10-32 FB
2-Piece Fitting
Tubing
(not included)
Ferrule
10-32 FB
NanoPort
Gasket
0.25”
(6.4 mm)
10-32 Coned Assembly
0.25”
(6.4 mm)
0.33”
(8.4 mm)
0.38”
(9.7 mm)
Tubing
(not included)
10-32 FB
2-Piece Fitting
10-32 Coned
NanoPort
Gasket
Reservoir Assembly
0.37”
(9.5 mm)
0.33”
(8.4 mm)
0.38”
(9.7 mm)
10-32 /1/4-28
Insert
0.30”
(7.6 mm)
1/4-28 FB
NanoPort
0.20”
(5.1 mm)
Gasket
NanoPort Adhesive Cure Requirements
Preformed Adhesive Rings (included with each order
Cure Temperature
Cure Time
165 – 177 ºC (330 – 350 ºF)
1 hour
Place clamped Ports in oven at a temperature of 165 – 177 ºC (330 – 350 ºF)
for one hour to develop a complete bond between the Port and
the substrate.
Please contact us regarding adherence to specifc polymer substrates
and other adhesive options.
Please Note: For alternative epoxy adhesive options, please contact
IDEX Health & Science directly.
NanoPort Reservoir Applications
Sample reservoir
Open wells for capillary electrophoresis
Syringe injection or fushing/priming, using our P-604 Luer Adapter,
page 56, and luer syringe (such as our B-310) on page 155
Application Note
FOR ORDERING & DISTRIBUTOR INFORMATION +1 800 426 0191 • +1 360 679 2528 • www.idex-hs.com