Page 74 - IDEX_Catalog20112012

This is a SEO version of IDEX_Catalog20112012. Click here to view full version

« Previous Page Table of Contents Next Page »
72
Tubing
DuPont HighPurity PFATubing
1/16”, 1/8”, 3/16” or 1/4” outside diameter available
PFA HP and PFA HP Plus Grades available
Virtually contaminant free
PFA High Purity (HP) tubing offers all of the benefts of standard PFA
tubing and more! This tubing is manufactured from a premium grade
of PFA that is one of the most contaminant-free polymers available.
PFAHP Plus tubing is available in 1/16” and 1/8”OD sizes. This polymer
grade has the same unsurpassed purity of PFA HP, with increased
ability to withstand repeated flexing and improved resistance to
stress cracking when exposed to aggressive fluorosurfactants.
Furthermore, tubing made from PFA HP Plus offers even smoother,
clearer walls than the standard PFA HP.
DuPont
®
PFATubing
1/16” and 1/8” ODs available
Excellent solvent resistance and low gas permeability
PFA (perfuoroalkoxyalkane) tubing offers excellent solvent resistance
(virtually identical to FEP and PTFE) while adding several advantages.
These include smoother surface texture, higher continuous service
temperature and superior polymer purity. The recommendedmaximum
operating temperature for our PFA tubing is 80 ºC.
360 µmODPFAHPPlus Tubing
Our capillary-sized tubing is manufactured from DuPont PFA HP Plus
polymer. This tubing is available in the most commonly-used outside
diameter for capillary tubing applications.
To cut this tubing to the length you need, we highly recommend our
A-350 Polymer Tubing Cutter (see page 74).
Once this tubing is held in place by connecting fttings, extra care
must be taken not to stretch the tubing, as this will likely cause
dimensional changes in both the OD and the ID of the tubing.
Low Pressure Tubing
Specifcations
PFA Tubing Specifcations
Tubing OD
OD Tolerances
Tubing ID
ID Tolerance
1/16”
±0.001” (25 µm)
All
±0.001” (25 µm)
1/8”
±0.003” (75 µm)
All
±0.003” (75 µm)
High Purity PFA Tubing Specifcations
Tubing OD
OD Tolerances
Tubing ID
ID Tolerance
1/16”
±0.001” (25 µm)
All
±0.001” (25 µm)
1/8”
±0.003” (75 µm)
All
±0.003” (75 µm)
3/16”
±0.003” (75 µm)
All
±0.003” (75 µm)
1/4”
±0.004 (0.10 mm)
All
±0.004 (0.10 mm)
360 µm OD PFA HP Tubing Specifcations
Tubing OD
OD Tolerance
Tubing ID
ID Tolerance
360 µm
±0.0005” (12.5 µm)
All
±0.0005” (12.5 µm)
Part No.
ID
Length Color Max. Pressure
PFA Tubing, 1/16” OD
1500
0.020” (0.50 mm) 5’ (1.5 m) Natural 2,000 psi (138 bar)
1511
0.020” (0.50 mm) 10’ (3 m) Natural 2,000 psi (138 bar)
1512
0.020” (0.50 mm) 20’ (6 m) Natural 2,000 psi (138 bar)
1512L
0.020” (0.50 mm) 50’ (15 m) Natural 2,000 psi (138 bar)
1502
0.030” (0.75 mm) 5’ (1.5 m) Natural 1,000 psi (69 bar)
1513
0.030” (0.75 mm) 10’ (3 m) Natural 1,000 psi (69 bar)
1514
0.030” (0.75 mm) 20’ (6 m) Natural 1,000 psi (69 bar)
1514L
0.030” (0.75 mm) 50’ (15 m) Natural 1,000 psi (69 bar)
1503
0.040” (1.0 mm) 5’ (1.5 m) Natural 500 psi (34 bar)
1504
0.040” (1.0 mm) 10’ (3 m) Natural 500 psi (34 bar)
1507
0.040” (1.0 mm) 20’ (6 m) Natural 500 psi (34 bar)
1507L
0.040” (1.0 mm) 50’ (15 m) Natural 500 psi (34 bar)
PFA Tubing, 1/8” OD
1508
0.062” (1.55 mm) 10’ (3 m) Natural 500 psi (34 bar)
1509
0.062” (1.55 mm) 20’ (6 m) Natural 500 psi (34 bar)
1509L
0.062” (1.55 mm) 50’ (15 m) Natural 500 psi (34 bar)
PFA HP Tubing, 1/16” OD
1620
0.020” (0.50 mm) 5’ (1.5 m) Natural 2,000 psi (138 bar)
1621
0.020” (0.50 mm) 10’ (3 m) Natural 2,000 psi (138 bar)
1622
0.020” (0.50 mm) 20’ (6 m) Natural 2,000 psi (138 bar)
1622L
0.020” (0.50 mm) 50’ (15 m) Natural 2,000 psi (138 bar)
1630
0.030” (0.75 mm) 5’ (1.5 m) Natural 1,000 psi (69 bar)
1631
0.030” (0.75 mm) 10’ (3 m) Natural 1,000 psi (69 bar)
1632
0.030” (0.75 mm) 20’ (6 m) Natural 1,000 psi (69 bar)
1632L
0.030” (0.75 mm) 50’ (15 m) Natural 1,000 psi (69 bar)
PFA HP Tubing, 1/8” OD
1640
0.062” (1.55 mm) 10’ (3 m) Natural 500 psi (34 bar)
1641
0.062” (1.55 mm) 20’ (6 m) Natural 500 psi (34 bar)
1641L
0.062” (1.55 mm) 50’ (15 m) Natural 500 psi (34 bar)
PFA HP Tubing, 3/16” OD
1642
0.125” (3.20 mm) 10’ (3 m) Natural 250 psi (17 bar)
1642L
0.125” (3.20 mm) 50’ (15 m) Natural 250 psi (17 bar)
1642XL 0.125” (3.20 mm) 100’ (30 m) Natural 250 psi (17 bar)
PFA HP Tubing, 1/4” OD
1645
0.188” (4.80 mm) 10’ (3 m) Natural 250 psi (17 bar)
1645L
0.188” (4.80 mm) 50’ (15 m) Natural 250 psi (17 bar)
1645XL 0.188” (4.80 mm) 100’ (30 m) Natural 250 psi (17 bar)
PFA HP Plus Tubing, 1/16” OD
1900
0.010” (0.25 mm) 5’ (1.5 m) Natural 3,000 psi (207 bar)
1901
0.010” (0.25 mm) 10’ (3 m) Natural 3,000 psi (207 bar)
1902
0.010” (0.25 mm) 20’ (6 m) Natural 3,000 psi (207 bar)
1902L
0.010” (0.25 mm) 50’ (15 m) Natural 3,000 psi (207 bar)
1905
0.020” (0.50 mm) 5’ (1.5 m) Natural 2,000 psi (138 bar)
1906
0.020” (0.50 mm) 10’ (3 m) Natural 2,000 psi (138 bar)
1907
0.020” (0.50 mm) 20’ (6 m) Natural 2,000 psi (138 bar)
1907L
0.020” (0.50 mm) 50’ (15 m) Natural 2,000 psi (138 bar)
1910
0.030” (0.75 mm) 5’ (1.5 m) Natural 1,000 psi (69 bar)
1911
0.030” (0.75 mm) 10’ (3 m) Natural 1,000 psi (69 bar)
1912
0.030” (0.75 mm) 20’ (6 m) Natural 1,000 psi (69 bar)
1912L
0.030” (0.75 mm) 50’ (15 m) Natural 1,000 psi (69 bar)
PFA HP Plus Tubing, 1/8” OD
1920
0.062” (1.55 mm) 10’ (3 m) Natural 500 psi (34 bar)
1921
0.062” (1.55 mm) 20’ (6 m) Natural 500 psi (34 bar)
1921L
0.062” (1.55 mm) 50’ (15 m) Natural 500 psi (34 bar)
PFA HP PLUS TUBING, 360 µm OD
1930
50 µm (0.002”)
5’ (1.5 m) Natural 3,500 psi (241 bar)
1931
75 µm (0.003”)
5’ (1.5 m) Natural 3,000 psi (207 bar)
1932
0.10 mm (0.004”) 5’ (1.5 m) Natural 2,500 psi (172 bar)
1933
0.15 mm (0.006”) 5’ (1.5 m) Natural 1,750 psi (121 bar)
Top Seller
See starred products