This is a SEO version of HAI_Price_List_2010. Click here to view full version
« Previous Page Table of Contents Next Page »22
POLYME R I C
High Speed Paraben Separation on a 1cm x 1mm PLRP-S
P/N PLP-0101-RP13
(1) Methylparaben, (2) Ethylparaben, (3) Propylparaben, (4) Butylparaben 50% MeCN/water, 50µL/min
PLRP-S PL-SAX PL-SCX PL-WAX PL-WCX
minutes
POLYMERIC
Unique Features:
• pH 1 to 14 operating range • Uniform hydrophobicity • Absence of any silanols • Very high selectivity
• Orthogonality for 2D methods • Mechanically and chemically robust
Physical Proper ties: • PLRP-S
Reverse phase media
100Å, 300Å, 1,000Å and 4,000Å Pore sizes 3µm and 5µm par ticle sizes • PL-SAX
Strong anion exchanger -N(CH 3 ) 3
+ 1,000Å and 4,000Å Pore sizes 5µm par ticle size • PL-SCX
Strong cation exchanger -SO 3
- 1,000Å and 4,000Å Pore sizes 5µm par ticle size • PL-WAX
Weak anion exchanger 1,000Å and 4,000Å Pore sizes 5µm par ticle size • PL-WCX
Weak cation exchanger 1,000Å and 4,000Å Pore sizes 5µm par ticle size
Applications
Higgins Analytical now manufactures a wide range of small column and car tridge formats with polymeric phases from Polymer Labs Ltd.
This powerful array of media provides chromatographers with unique solutions for challenging HPLC applications. In addition to not having the pH limitations inherent to all silica-based sorbents, these polymeric phases provide an or thogonal tool for addressing difficult protocols and multidimensional techniques.The relatively high capacity and unique selectivity of these robust phases can often provide a separation under harsh conditions that cannot be addressed with popular silica-based columns.
The rigid porous structure and chemical stability of Polymer Labs media make them compatible with the wide range organic solvents typically used in modern HPLC methods. In addition to insuring long mechanical and chemical life times, this robustness also provides an ability for these polymeric phases to be rejuve-nated under chemical and thermal conditions that would be unthinkable to subject a conventional HPLC column.
The uniform hydrophobicity and absence of acidic silanols make this family of polymeric phases ideal for many biomolecule separations.
Guide to POLYMERIC Part Numbers
PLx-xxxx-RP13 PLRP-S 100Å 3µm PLx-xxxx-RP33 PLRP-S 300Å 3µm PLx-xxxx-RP1K5 PLRP-S 1,000Å 5µm PLx-xxxx-RP4K5 PLRP-S 4,000Å 5µm PLx-xxxx-SAX1K5 P-SAX 1,000Å 5µm PLx-xxxx-SAX4K5 P-SAX 4,000Å 5µm PLx-xxxx-WAX1K5 P-WAX 1,000Å 5µm PLx-xxxx-WAX4K5 P-WAX 4,000Å 5µm PLx-xxxx-SCX1K5 P-SCX 1,000Å 5µm PLx-xxxx-SCX4K5 P-SCX 4,000Å 5µm PLx-xxxx-WCX1K5 P-WCX 1,000Å 5µm PLx-xxxx-WCX4K5 P-WCX 4,000Å 5µm
See Page 23 for complete Part Number information
PLRP-S
This is a SEO version of HAI_Price_List_2010. Click here to view full version
« Previous Page Table of Contents Next Page »