Page 139 - IDEX_Catalog20112012

This is a SEO version of IDEX_Catalog20112012. Click here to view full version

« Previous Page Table of Contents Next Page »
137
Valves
Valco/VICI-CompatibleStainless Steel SampleLoops
Valco-Compatible Stainless Steel Loops are manufactured by IDEX
Health & Science. These loops are designed for use with Valco valve
models CW6 and EC6W. Each loop has burr-free, polished ends and
is passivated and flushed with reagent-grade methanol to ensure
cleanliness.
Loops made with 1/16” OD tubing come complete with F-287
SealTight
Fittings, which are pressure rated to 9,000 psi (620 bar)
1
.
The fttings and adapters that accompany the 1/8” OD sample loops
are rated to 1,000 psi (69 bar)
1
. Volumes are stated at ±10%, with
exact calibration services available. Each sample loop we calibrate is
documented and supplied with a calibration certifcate.
Sample Loops
PEEK
Sample Loops
Flexible PEEK sample loops are alternatives to stainless steel loops.
PEEK loop ends are provided with clean, straight cuts for easy valve
installation.
PEEK polymer is inert to almost al l organic solvents and is
biocompatible, giving PEEK loops added versatility. Natural PEEK is
used for these sample loops. Like metal loops, the size designations
of PEEK loops are nominal. The actual volumes can differ from the
theoretical designations because of the ±0.05 mm (0.002”) tolerance
of the tubing bore. Accuracy of large PEEK loops (0.8mm, 0.030” bore)
is about ±14%, intermediate loops (0.5 mm, 0.020”) ±21%, and small
loops (0.2 mm, 0.007”) ±65%.
PEEK loops are also supplied with unswaged RheFlex fttings but do
not require the same swaging precaution. The fttings can reposition
along the loop tubing when the ftting reinserts in the ports for correct
loop installation.
Please Note: Several of our PEEK Sample Loops can also be used with
Valco/VICI
®
sample injectors. Please refer to the product lising on this
page to aid selection.
Part No. Volume
Tubing
Valco No.
PEEK Loops for 3725, 3725i Injectors
3055-018 2.0 mL Sample Loop 1.6 mm (0.062”) ID x 1/8” OD N/A
3055-019 5.0 mL Sample Loop 1.6 mm (0.062”) ID x 1/8” OD N/A
3055-023 10 mL Sample Loop 2.0 mm (0.080”) ID x 1/8” OD N/A
3055-025 20 mL Sample Loop 2.0 mm (0.080”) ID x 1/8” OD N/A
PEEK Loops for 9725, 9010, PR/EV750-100, PR/EV753-100 Injectors
Part No. Volume
Bore / Tubing
Valco No.
9055-020 5.0 µL Sample Loop 0.18 mm (0.007”) ID x 1/16” OD SL5CWPK
9055-021 10 µL Sample Loop 0.25 mm (0.010”) ID x 1/16” OD SL10WPK
9055-022 20 µL Sample Loop 0.25 mm (0.010”) ID x 1/16” OD SL20WPK
9055-023 50 µL Sample Loop 0.51 mm (0.020”) ID x 1/16” OD SL50WPK
9055-024 100 µL Sample Loop 0.51 mm (0.020”) ID x 1/16” OD SL100WPK
9055-025 200 µL Sample Loop 0.51 mm (0.020”) ID x 1/16” OD N/A
9055-026 500 µL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD SL500WPK
9055-027 1.0 mL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD SL1KCWPK
9055-028 2.0 mL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD SL2KCWPK
9055-029 5.0 mL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD N/A
9055-033 10 mL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD N/A
PEEK Loops for 7725, 7725i, PR/EV700-100
7123-227 1 µL Sample Loop
internal groove
N/A
(model PR/EV700-100 only)
7755-015 2 µL Sample Loop
internal groove
N/A
(models 7725 and 7725i only)
Replacement RheFlex fittings for peek loops
Part No. Description
Qty.
6000-078 Nut/Ferrule Set, Natural PEEK, 5/16-24, for 1/8” OD loops ea.
6000-079 Ferrules, Natural PEEK, for 1/8” OD loops
5-pk
6000-251 Ferrules, Natural PEEK, for 1/16” OD loops
10-pk
6000-254 Nut/Ferrule Sets, Natural PEEK, 10-32, for 1/16” OD loops 10-pk
Valco/VICI-Compatible Stainless Steel Loops for C6W, ec6w injectors
Part No. Volume
Tubing
Valco No.
1750
5 µL Sample Loop
0.18 mm (0.007”) ID x 1/16” OD SL5CW
1751
10 µL Sample Loop 0.25 mm (0.010”) ID x 1/16” OD SL10CW
1752
15 µL Sample Loop 0.25 mm (0.010”) ID x 1/16” OD SL15CW
1755
20 µL Sample Loop 0.51 mm (0.010”) ID x 1/16” OD SL20CW
1758
25 µL Sample Loop 0.51 mm (0.010”) ID x 1/16” OD SL25CW
1759
50 µL Sample Loop 0.51 mm (0.020”) ID x 1/16” OD SL50CW
1762
100 µL Sample Loop 0.51 mm (0.020”) ID x 1/16” OD SL100CW
1778
200 µL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD N/A
1763
250 µL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD SL250CW
1764
500 µL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD SL500CW
1770
1 mL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD SL1KCW
1772
2 mL Sample Loop 1.02 mm (0.040”) ID x 1/16” OD SL2KCW
1775
5 mL Sample Loop 2.03 mm (0.080”) ID x 1/8” OD SL5KCW
1776
10 mL Sample Loop 2.03 mm (0.080”) ID x 1/8” OD SL10KCW
Application Note
PEEK Physical Strength Characteristics
Although PEEK material is compatible with virtually all solvents, there are
many factors that affect burst pressure of PEEK tubing. Factors such as
increases in inner diameter, temperature, exposure time, and concentration
of organic solvents affect the degradation of PEEK. Other solvents such
a THF, methylene chloride and DMSO cause PEEK tubing to swell while
concentrated nitric acid and sulfuric acid weaken the tubing.
1
These pressure ratings refect the
performance of the fttings, not the
port or valve in which they are used.
IDEX Health & Science manufactures many
products designed as direct replacements for OEM
components. Reference to these manufacturers
does not imply their endorsement of our products.
FOR ORDERING & DISTRIBUTOR INFORMATION +1 800 426 0191 • +1 360 679 2528 • www.idex-hs.com