178
Debubblers & Degassers
Stand Alone Prep Scale Degassers
Systec
®
StandAlonePrepScaleVacuum
DegassingSystem
Ultra-high degassing effciency
Low volume, easy to prime
Patented control eliminates baseline fuctuations
Dual lumen design for low-fow resistance
Inert fow path
5+ year lifetime
The Systec StandAlone Prep Scale vacuumdegassing system for HPLC
is a high effciency in line module that removes dissolved gasses from
HPLC mobile phases. Built for the rigors of modern preparative and
semi-prep scale HPLC, its unique design assures reliable continuous
operation and the highest level of continuous performance available.
Two solvent lines may be degassed simultaneously by one unit.
ZHCR
®
Control with Built-in Test Diagnostics
Microcontroller self-test vacuum sensor validationon power-up
Continuous vacuum system monitoring to ensure optimum
operational conditions are maintained
Vacuum system fault detection and shutdown function indicators
AF / ZHCR Degassing Technology
The prep / semi-prep scale degassing chambers are designed to
be easy to prime, and are confgured with a Systec AF
®
degassing
membrane to providemaximumdegassing capacity with the absolute
minimum internal volume (<3% of PTFE designs with comparable
degassing capacity).
The ZHCR (Zero Hysteresis / Constant Run) vacuum pump employs a
patented closed-loop, micro-stepping RPMcontrol strategy permitting
the pump to run with continuously variable speed, providing quick
pull-down at high RPM, and then sustaining a consistent vacuum level
at low RPM.
Fluctuations in detector baseline due to changes in vacuum level are
eliminated by not having to repeatedly stop and start a single-speed
pump. This also greatly reduces wear and noise.
The brushless motor enables quiet operation and is appropriate for
environments where solvent vapors may be present.
Part No. Number of Channels
Volume Per Channel
Max HPLC Gradient
Flow Capability
C
Pressure Drop
D
Degassing Flow Path ID
SYSTEC STAND ALONE PREP SCALE VACCUUM DEGASSING SYSTEMS – AVAILABLE CONFIGURATIONS
A, B
0001-6482 2
8.4 mL
20 mL/min
0.04 bar/mL/min
0.065” (1.65 mm)
0001-6484 2
13.8 mL
40 mL/min
0.06 bar/mL/min
0.065” (1.65 mm)
A. Custom confgurations are available. Consult us for your own OEM solution to your specifc application.
B. The standard prep scale chambers are not recommended for GPC applications or for use with HFIP (hexafuoroisopropanol).
C. The fow rates given are for a gradient mixture of 60/40 MeOH/H
2
O, with a typical low pressure gradient mixing valve. Higher fow rates are possible with high pressure mixing.
D. Estimated tubing pressure per unit change in fow assuming laminar fow with a viscosity of 1.0 cP
Overall Dimensions
POWER STATUS VACUUM
3.12
[79mm]
6.42
[163mm]
11.67
[296mm]
EXHAUST
VALIDATION
POWER
15-24V
DC
0.85A MAX.
6.42”
(163 mm)
3.12”
(79 mm)
11.67”
(296 mm)
Top Seller
SEE STARRED PRODUCTS
Validation Output
A 2-pin rear panel receptacle labeled “Validation” with mating screw-lock
plug is provided to allow a validation signal from the control circuit to be sent
to a computer or data system. This validation output indicates vacuum level.
Signal:
5mV DC / 0.13 bar (1 mmHg) absolute from 2.7 to
106.7 bar (20 to 800 mmHg) (0.100V DC at 2.7 bar
(20 mmHg); 4.000V DC at 106.7 bar (800 mmHg)
Accuracy:
±1.0% of reading ±0.010V DC from 2.7 to 106.7 bar (20 to 800 mmHg)
Power Requirement
Input Power required with AC Adapter (included):
100 to 240V AC (±10%), 1A, 50 to 60 Hz (±3 Hz)
Four interchangeable wall sockets are supplied with the AC Adapter:
North America/Japan, U.K., Continental Europe, Australia.
CE Certifcation
This product has been certifed under the following CE testing standards:
EN61326-1; EN55011; EN61300-3-2; EN61300-3-3 & EN61010-1.
Note
FOR ORDERING & DISTRIBUTOR INFORMATION +1 800 426 0191 • +1 360 679 2528 • www.idex-hs.com